Airstream™ Stack Fan Coil 42S 300 to 2,000 Cfm
Carrier Fan Coils Malaysia Air Conditioner Fan Coil Malaysia Fan Coil Malaysia Air Cond Fan Coil Malaysia Carrier Stack Fan Coil 42S Malaysia
42SGA – Furred-in
Performance Features
42SHA – Cabinet
42SJA – Furred-in, Back-to-Back
42SMA – Furred-in, Mega
42SUB - Furred-in, Universal
Ideal for installation in high-rise applications, 42S fan coils combine heating and cooling performance with easy, low-cost installation. The 42S units are factory equipped with insulated supply, return, and drain risers, which allow them to be set one on top of another in a vertical column rising floor to floor up the building. Units are available in furred-in, painted cabinet, and back-to-back models. Custom colors allow the unit to blend with any interior design.
- Airflow capacities from 300 to 2000 CFM
- 2-pipe or 4-pipe system combinations
- Economical, 3-speed fans deliver the right amount of conditioned air for comfort needs at any load
- Optional electronically commutated motors deliver peak operating efficiency
- Sound-absorbing insulation is used to line the cabinet
- Outside air opening with or without adjustable damper (0 to 25%) (factory-installed option)
- Certified performance in accordance with AHRI Standard 440
Reliability Features
- Coils are factory leak tested at 300 psig air pressure with coil submerged in water
- All equipment wiring complies with NEC requirements
- Base units are ETL certified for USA and Canada standards
- Unit casing meets UL 181 and NFPA 90A standards
- Factory-installed supply, return, and drain risers can be furnished in type M or L copper
Maintenance Features
- Cleanable or throwaway filters available
- The return air panels is removable, to allow access for servicing major components
- Tamperproof locks on access panels
- Label information adhered to each unit includes model, size, coil information, electrical information, and tagging data
- Condensate drain pans are available in stainless steel or heavy gage galvanized steel constructions, along withoptional condensate overflow switches
Installation Features
- Valve packages available (factory-installed option)
- Risers are insulated with flexible closed cell foam insulation
- Risers include a 3 in. belled section at the top enabling the use of only one sweat connection per riser piping connection
- Riser length can be specified to match building requirements
- All units arrive tagged as specified by the customer for efficient delivery to the correct building location
- Factory-installed controls
- Single point electrical connection
Factory-Installed Options
- 3-speed switches
- Line voltage thermostats
- 24 v Carrier Debonair® programmable or non-programmable thermostats
- Product Integrated direct digital electronic controls (i-Vu® control system using BACnet protocol)
- Chilled water or direct expansion cooling coils
- Hot water or steam heating coils
- Total or auxiliary electric heat
- Service switches
- Custom colors
- Permanent or throwaway filters
- Automatic air vent and drain on water coils
- Double deflection discharge grilles and opposed blade dampers
- Tell-tale drains and stainless steel drain pans
- Condensate overflow switch
- Dual density fiberglass, foil faced fiberglass or closed cell insulation
- PSC, High Static PSC, or ECM motors
- Outside air damper
- Valve packages
- 1-hr fire rated chase between back-to-back units
- Stamped or louvered return air panels (shipped loose)
- Insulated supply, return, and drain risers
- Standard height (88 in.) or short cabinet height (79 in.) available
Field-Installed Accessories
- Remote mounted thermostats
Unit Size 42S | 03 | 04 | 06 | 08 | 10 | 12 | 14 | 16 | 20 |
---|---|---|---|---|---|---|---|---|---|
Nominal Airflow (Cfm) | 300 | 400 | 600 | 800 | 1000 | 1200 | 1400 | 1600 | 2000 |
Shipping Weight (lb)* | |||||||||
42SGA, SGM, SU | 180 | 225 | 240 | 260 | 280 | 305 | -- | -- | -- |
42SH | 202 | 247 | 262 | 286 | 311 | 336 | -- | -- | -- |
42SJ | 360 | 450 | 480 | 520 | 560 | 610 | -- | -- | -- |
42SGS | 162 | 203 | 216 | 234 | 252 | 275 | -- | -- | -- |
42SM | -- | -- | -- | -- | -- | -- | 390 | 390 | 390 |
Coil Water Weight (Approx. lb per row of coil) |
1.79 | 2.63 | 3.45 | 4.09 | 4.09 | 4.39 | |||
Coils (fpi) | 14 fins/inch | ||||||||
Blower (qty) | |||||||||
42SGA, SH, SU, SGM, SGS, SM | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
42SJ | 2 | 2 | 2 | 2 | 2 | 2 | -- | -- | -- |
Filters | |||||||||
Nominal Size (in) (1-in. thick) | 12-1/2 x 24-1/4 | 16-1/4 x 26-1/4 | 20-1/2 x 29-1/4 | 24-1/2 x 29-1/2 | 26-1/2 x 29-1/2 | ||||
Qty | 1† | ||||||||
Piping Connections Inlet (in. OD) |
1/2 unless larger size valve package is selected |
*Calculate Operating Weight of Unit: Shipping Weight + Coil Water Weight x Number of Coil Rows
†42SJ units require two filters.