Gemini® Select Air-Cooled Condenser 09DP with Puron® Refrigerant (R-410a) 18 to 130 Nominal Tons
Gemini® Select Air-Cooled Condenser 09DP with Puron® Refrigerant (R-410a) 18 to 130 Nominal Tons Carrier  Air Cooled Condensers  Split Systems and Condensers Selangor, Malaysia, Kuala Lumpur (KL), Singapore, Puchong, Petaling Jaya (PJ), Pandan Jaya Supplier, Suppliers, Supply, Supplies | United Faith Sdn Bhd

with Puron® Refrigerant (R-410a)

18 to 130 Nominal Tons

These condensers feature one or two independent refrigerant circuits depending on the unit size. All units are factory wired, nitrogen charged, and easily connected by refrigerant lines and control wiring to the matching Carrier split chiller. Various combinations of these extremely flexible condensers matched with the compressor /evaporator section provide customized packages to cover a wide range of cooling requirements. Low roof-load weight distribution and weatherproof construction make these units excellent selections for rooftop or on-the-ground installations. The 09DPs are well suited for commercial or industrial air conditioning applications.


carrier-c-ul-us
carrier-ul-registered-mark-with-id-number

Performance Features

  • High short circuit interrupt protection option
  • Motormaster® V low ambient temperature controller option
  • Single (09DPS) and multiple (09DPM) split combinations
  • AeroAcoustic low sound fan option

Reliability Features

  • MCHX coil with E-coating option
  • Galvanized steel cabinet, bonderized and finished with baked enamel, 500-hour salt-spray test
  • Non-fused disconnect protection option
  • Security grilles/hail guards option
  • V-coil design (065-130 models)
  • UL and UL, Canada approved

Installation Features

  • On-the-ground or rooftop installation
  • Small footprint
  • Single circuit manifold tubing kit with all 09DPM model
  • Fork truck lift pockets (018-060) and lifting holes in base rail construction (065-130 models)

Factory-Installed Options

  • Condenser Coil/Low Sound Options
    • E-Coated MCHX
    • Low Sound Fan(s)
  • Ambient/Capacity Control/Interrupt Options
    • High Short Circuit Current Rating Interrupt
    • Motormaster V Low Ambient Control
  • Electrical Options
    • Non-Fused Disconnect
  • Packaging/Security Options
    • Bottom Skid
    • Bottom Skid, Top Crate, Bag
    • Security Grilles/Hail Guards

Field-Installed Accessories

  • Condenser Coil/Low Sound Options
    • Low Sound Fan(s)
    • Vibration isolation Pads
  • Ambient/Capacity Control/Interrupt Options
    • Motormaster V Low Ambient Control
  • Packaging/Security Options
    • Security Grilles/Hail Guards
    • Wind Baffles

Model Total Heat of Rejection (Tons) Number of Refrigerant Circuits Total Operating Weight (lbs)
09DPS018 20.7 1 638
09DPS020 33.1 1 719
09DPS030 37.7 1 869
09DPM035 43.3 2 1126
09DPM040 54.9 2 1204
09DPM050 66.4 2 1282
09DPM060 75.3 2 1524
09DPM065 85.8 2 1622
09DPM075 107.6 2 1846
09DPM085 115.6 2 1933
09DPM095 129.4 2 1933
09DPM115 149.4 2 2447
09DPM130 172.0 2 2533

Total heat of rejection based on a 15°F subcooling and 30°F difference between saturated condensing temperature and the outdoor ambient.

Dimensions

Model Length (ft-in) Height (ft-in) Width (ft-in)
09DPS018 7-5 5-1 3-5
09DPS020 7-5 5-1 3-5
09DPS030 7-5 6-2 3-5
09DPM035 7-9 5-1 7-5
09DPM040 7-9 5-1 7-5
09DPM050 7-9 5-1 7-5
09DPM060 7-9 5-1 7-5
09DPM065 9-3 6-1 7-5
09DPM075 12-8 6-1 7-5
09DPM085 12-8 6-1 7-5
09DPM095 12-8 6-1 7-5
09DPM115 16-0 6-1 7-5
09DPM130 16-0 6-1 7-5

Electrical Data

Model MCA 208/230 MOCP MCA 380 MOCP MCA 460 MOCP MCA 575 MOCP
09DPS018 8.3 15 4.9 15 4.1 15 3.3 15
09DPS020 14.9 20 8.8 15 7.4 15 5.9 15
09DPS030 14.9 20 8.8 15 7.4 15 5.9 15
09DPM035 14.9 20 7.4 15 7.4 15 5.9 15
09DPM040 212.5 25 12.7 15 10.7 15 8.5 15
09DPM050 28.1 30 16.6 20 14.0 15 11.0 15
09DPM060 28.1 30 16.6 20 14.0 15 11.1 15
09DPM065 28.1 30 16.6 20 14.0 15 11.1 15
09DPM075 34.7 40 20.5 25 17.3 20 13.7 15
09DPM085 41.3 45 24.4 25 20.6 25 16.3 15
09DPM095 41.3 45 24.4 25 20.6 25 16.3 15
09DPM115 47.9 45 23.9 25 23.9 25 18.9 20
09DPM130 54.5 60 32.2 35 27.2 30 21.5 25

MCA = Minimum Circuit Amps
MOCP = Maximum Overcurrent Protection